中圖分類號(hào):X703:TU992.3 文獻(xiàn)標(biāo)志碼:A 文章編號(hào):1004-4345(2025)03-0041-05
AbstractAimingatthelowinfluent pollutantconcentrationinurban wastewatertreatment plants,thispaper takesthe W8 wastewatercolectionzoneindowntown Chenzhouasthestudyobject.Basedonmonitoringdataof waterqualityflowinthe pipelinenetwork,theprimarycausesoflowregionalwastewaterconcentrationsignificantexteralwaterintrusion(dry-season intrusion rate reaching 46.99% ) were analyzed. Targeted technical measures were proposed, including pipeline network renovation, externalwaterseparationlocalizedsource-levelstor-wastewaterseparatio.Analysisofextealwaterremovalefectivenes demonstrates thatchemicaloxygendem(COD)inthezone'smainefluent pipelineisexpectedtoincreasefrom78.3mg/Lto 104.2 mg/L after implementation of this proposal. The planned target of 100mg/L will bestablyachieved,thereby effectively enhancing wastewater treatment efficiency water quality.
wordswastewatersystem;qualityeficiencyenhancement;wastewater network monitoring;external waterintrusion; chemical oxygen dem (COD)
隨著城市化進(jìn)程的推進(jìn),我國(guó)城鎮(zhèn)污水收集處理設(shè)施得到快速普及,污水收集率和處理率逐年提升。然而,污水處理廠進(jìn)水濃度偏低問(wèn)題依然突出,這在南方特別是長(zhǎng)江流域更為明顯。據(jù)研究,長(zhǎng)江沿線6省共計(jì)191座污水處理廠的進(jìn)水生化需氧量 BOD5 ),均值僅 。2022年,住房城鄉(xiāng)建設(shè)部、生態(tài)環(huán)境部、國(guó)家發(fā)改委、水利部聯(lián)合印發(fā)《深入打好城市黑臭水體治理攻堅(jiān)戰(zhàn)實(shí)施方案》,明確提出到2025年城市生活污水集中收集率要達(dá)到 70% ,進(jìn)水 BOD5gt;100mg/L 的污水處理廠規(guī)模占比超90% ?,F(xiàn)狀距此目標(biāo)差距顯著。如湖南省目前達(dá)標(biāo)的污水處理廠進(jìn)水 BOD5 濃度高于 100mg/L 的規(guī)模占總規(guī)模的比例僅為 25.1% ,因此,精準(zhǔn)診斷管網(wǎng)濃度偏低的成因,并據(jù)此制定科學(xué)合理的進(jìn)水濃度提升方案,是當(dāng)前污水系統(tǒng)提質(zhì)增效的關(guān)鍵。
本研究以郴州中心城區(qū)W8污水納污片區(qū)為研究對(duì)象,針對(duì)該區(qū)污水廣進(jìn)廣濃度偏低問(wèn)題,通過(guò)管網(wǎng)水質(zhì)、水量監(jiān)測(cè)等手段,分析研究進(jìn)廠濃度偏低的主要原因,并據(jù)此提出污水系統(tǒng)濃度提升的改造對(duì)策。
1項(xiàng)目概況
1.1片區(qū)排水系統(tǒng)概況
郴州市位于湖南省東南部,屬亞熱帶濕潤(rùn)季風(fēng)氣候區(qū),地勢(shì)南高北低,長(zhǎng)江和珠江水系在此分流。該市中心城區(qū)總面積為 164.77km2 ,其中西城區(qū)約為 102.24km2 ,包括第一、第二、第四污水收集處理系統(tǒng),如圖1所示。第一與第四污水收集系統(tǒng)邊界模糊,形成了老城區(qū)合流制與分流制共存的“混合型”系統(tǒng)。位于西城區(qū)北部的下湄橋第一污水廠,主要負(fù)責(zé)老城區(qū)的生活污水;在其下游的第四污水處理廠則負(fù)責(zé)接納超出第一污水處理廠處理能力的水量。第一、第四污水處理廠現(xiàn)狀最大處理規(guī)模分別為1.2×105m3/d 和 6.0×104m3/d, 0
本次研究對(duì)象W8片區(qū),位于郴州市中心老城區(qū),面積為 16.05km2 。研究區(qū)內(nèi)排水體制以合流制為主,已建污水管總長(zhǎng) 44.5km ,合流管總長(zhǎng) 77.1km ,污水主要沿郴江河DN1650 截污干管 -2.6m×2.0m 燕泉河DN1200截污干管、同心河 DN1000 截污干管以及北干渠 3.0m×2.0m 合流箱涵接人第一、第四污水處理廠。
1.2污水處理廠進(jìn)廠濃度現(xiàn)狀
根據(jù)水質(zhì)監(jiān)測(cè)結(jié)果,第一污水處理廠2019年1月—2021年6月期間,進(jìn)水化學(xué)需氧量(COD)為98~150mg/L ,見(jiàn)圖2。2021年7月—2021年12月期間,由于餐廚垃圾匯入污水管道,第一污水處理廠進(jìn)水COD翻倍,基本維持在 200mg/L 以上,其中 2021年9月和10月的進(jìn)水COD峰值 gt;450mg/L? 。剔除該時(shí)間段進(jìn)水?dāng)?shù)據(jù)后,第一污水處理廠平均進(jìn)水COD為 130mg/L 。第四污水處理廠進(jìn)水COD變化不明顯,2019年1月—2022年4月月度平均進(jìn)水COD為 97mg/L 。
2管網(wǎng)監(jiān)測(cè)方案
研究表明[4-5],外水入侵污水管道嚴(yán)重影響污水處理系統(tǒng)的能效發(fā)揮。因此,本研究采用分區(qū)診斷的方法排查管網(wǎng)外水,即根據(jù)現(xiàn)狀管道數(shù)據(jù)進(jìn)行拓?fù)浞治雠c分區(qū)劃定,明確不同層級(jí)的邊界,并根據(jù)監(jiān)測(cè)目標(biāo)建立粗分區(qū)一精細(xì)網(wǎng)格的層級(jí)模型。具體排查流程如下。
1)開(kāi)展基礎(chǔ)資料收集工作,包含管網(wǎng)排查資料、污水處理廠水質(zhì)水量資料和區(qū)域用水量數(shù)據(jù)等。2)根據(jù)基礎(chǔ)資料分析情況,確定監(jiān)測(cè)方案,包括區(qū)域監(jiān)測(cè)指標(biāo)及頻次、排水分區(qū)劃分及監(jiān)測(cè)點(diǎn)位等。3)根據(jù)監(jiān)測(cè)水質(zhì)水量數(shù)據(jù)結(jié)果鎖定管網(wǎng)問(wèn)題突出區(qū)域。4)通過(guò)現(xiàn)場(chǎng)踏勘、CCTV、QV、水質(zhì)水量監(jiān)測(cè)分析等工作制定外水精細(xì)化摸排方案。
2.1監(jiān)測(cè)布點(diǎn)
監(jiān)測(cè)布點(diǎn)應(yīng)覆蓋截污主干管及沿線主要支管匯入點(diǎn)。布點(diǎn)方案需依據(jù)污水分區(qū),結(jié)合管網(wǎng)結(jié)構(gòu)、水力拓?fù)浣Y(jié)構(gòu)、區(qū)塊面積、覆蓋人口、管網(wǎng)長(zhǎng)度等要素合理制定。在保障監(jiān)測(cè)效果的基礎(chǔ)上,兼顧經(jīng)濟(jì)合理性。重點(diǎn)監(jiān)測(cè)區(qū)域?yàn)檠睾觾蓚?cè)的截污干管。該段區(qū)域管網(wǎng)內(nèi)液位較高,長(zhǎng)期處于高負(fù)荷運(yùn)行狀態(tài),排水較為困難,故需重點(diǎn)排查區(qū)域內(nèi)入流入滲點(diǎn)。
2.2水質(zhì)水量監(jiān)測(cè)方案
對(duì)污水管網(wǎng)進(jìn)行概化分析,建立由主干管為骨干并向上游溯源分級(jí)的污水系統(tǒng)拓?fù)浣Y(jié)構(gòu),不同管段分為一級(jí)支管、二級(jí)支管等。
依據(jù)同心河和郴江兩側(cè)截污干管的走向,在干管主要節(jié)點(diǎn)、重要支管匯入節(jié)點(diǎn)及污水分區(qū)邊界處布設(shè)監(jiān)測(cè)點(diǎn),共計(jì)15個(gè)。所有點(diǎn)位監(jiān)測(cè)COD及管道流量,具體檢測(cè)要求如下:流量連續(xù)監(jiān)測(cè)14d,COD監(jiān)測(cè)時(shí)間為連續(xù)3個(gè)晴天,采樣頻率為每天4次,時(shí)段分別為早上(7:00—9:00)、中午(12:00—14:00)、晚上(18:00—20:00)夜間(0::00—2:00)。監(jiān)測(cè)布點(diǎn)及分區(qū)見(jiàn)圖3。其中,A8監(jiān)測(cè)點(diǎn)為本研究區(qū)最終匯流點(diǎn),具體位于郴江河左岸DN1650截污干管內(nèi)。
3 管網(wǎng)監(jiān)測(cè)結(jié)果分析
3.1市政管網(wǎng)水質(zhì)水量監(jiān)測(cè)結(jié)果
將監(jiān)測(cè)點(diǎn)的水質(zhì)水量取平均值,綜合得到W8片區(qū)整體水量拓?fù)潢P(guān)系如圖4。
片區(qū)監(jiān)測(cè)總水量為 84560m3/d(QA8-QE+QA9+ QB3 ),監(jiān)測(cè)點(diǎn)的COD范圍為 78.3~95.5mg/L(lt;100 mg/L )。其中,A8節(jié)點(diǎn)為片區(qū)的污水主干管出口,COD檢測(cè)結(jié)果見(jiàn)圖5。
由圖5可知,A8節(jié)點(diǎn)COD檢測(cè)結(jié)果為62\~98mg/L,3 天COD平均值為 78.3mg/L 。市政管網(wǎng)水質(zhì)水量監(jiān)測(cè)結(jié)果見(jiàn)圖6。郴江河左岸監(jiān)測(cè)點(diǎn)(A1\~A6)干管管徑為 DN800~DN1800 ,末端總水量為10.8萬(wàn) m3/d ,干管COD 范圍為 115.0~78.9mg/L? 。整體質(zhì)量濃度較低,且呈現(xiàn)從上游往下游遞減趨勢(shì),表明管道沿線存在外水進(jìn)入。
北干渠主干管監(jiān)測(cè)點(diǎn)(A11\~A15)污水主干管為北干渠合流箱涵( 3.0m×2.0m ),末端總水量為5.9萬(wàn) m3/d ,末端COD為 84.4mg/L 。主干管的COD質(zhì)量濃度較低,表明管網(wǎng)系統(tǒng)存在一定量的外水。其中,A12 監(jiān)測(cè)點(diǎn)(沿湖箱涵段)的COD平均僅為 26.0mg/L ,表明該區(qū)域存在大量湖水入滲。
3.2源頭水質(zhì)水量監(jiān)測(cè)結(jié)果
在源頭水質(zhì)監(jiān)測(cè)方面,研究區(qū)共布置監(jiān)測(cè)點(diǎn)353個(gè)。源頭水量水質(zhì)采用快檢法,結(jié)果為瞬時(shí)值
1)片區(qū)源頭水質(zhì)水量監(jiān)測(cè)結(jié)果。研究區(qū)源頭監(jiān)測(cè)結(jié)果如圖7、圖8所示,研究區(qū)污水量主要源自合流制排水單元出流,為14.74萬(wàn) m3/d ,占本片區(qū)源頭總產(chǎn)污水量的 87% 。所有地塊平均COD為 86.4mg/L ,分流制和合流制排水單元的平均COD出水質(zhì)量濃度分別為 84.8mg/L 和 97.8mg/L
據(jù)圖8所示,本片區(qū)污水主要來(lái)源于小區(qū)(10.53萬(wàn) m3/d ,占比 62.4% ),其次為商業(yè)(污水量4.16萬(wàn) m3/d ,占比 24.6% ),第3為醫(yī)院(污水量1.20萬(wàn) m3/d ,占比 7.1% )。根據(jù)各地塊出水COD分析,僅垃圾站和餐飲單元出水的COD超過(guò) 100mg/L 而最大產(chǎn)污單元(小區(qū))的出水COD平均為 89.5mg/L ,低于預(yù)期水質(zhì)考核目標(biāo)。同樣,污水量較大的商業(yè)和醫(yī)院地塊出水COD平均為 92.0mg/L 和 70.6mg/L ,亦低于預(yù)期水質(zhì)考核目標(biāo)。
3.3水量平衡分析
根據(jù)自來(lái)水公司抄表數(shù)據(jù),研究區(qū)日均用水量為7.99萬(wàn) m3/d ,理論污水量按用水總量的 85% 折算,約為6.79萬(wàn) m3/d 。通過(guò)比較理論污水量和實(shí)際監(jiān)測(cè)排水量之間的差值,可以計(jì)算得到片區(qū)的理論外水量為6.02萬(wàn) m3/d ,具體計(jì)算結(jié)果詳見(jiàn)表1。
由表1可知,片區(qū)監(jiān)測(cè)污水總量為8.46萬(wàn) m3/d 污水外溢量為4.35萬(wàn) m3/d 。據(jù)此計(jì)算可得,污水管網(wǎng)旱季外水入侵率為 6.02/(8.46+4.35)×100%= 46.99% 。
本片區(qū)外水主要來(lái)源于 W8-6 北湖周邊片區(qū),外水量為3.51萬(wàn) m3/d ,占理論總外水量的 58.26% :其次是W8-7片區(qū),外水量為1.71萬(wàn) m3/d ,占總外水量的 28.46% ,其余5個(gè)片區(qū)外水占比合計(jì)為13.28% 。因此, W8–6 和W8-7片區(qū)是外水治理的重點(diǎn)區(qū)域。
3.4外水調(diào)查分析
基于管網(wǎng)水質(zhì)水量分析,初步確定主要外水入侵片區(qū)后,通過(guò)人工排查進(jìn)一步精調(diào),定位集中外水匯入點(diǎn)。排查重點(diǎn)區(qū)域?yàn)閃8-6和W8-7片區(qū),重點(diǎn)管道為截污干管、合流箱涵、北湖片區(qū)周邊沿湖管道以及施工工地。
已查明外水量約為4.17萬(wàn) m3/d ,其中地表水(北湖湖水)量為1.75萬(wàn) m3/d ,占外水總量的 41.97% :地下水入滲水量為0.70萬(wàn) m3/d ,占比 17.99% ;地下車庫(kù)抽排水水量為0.64萬(wàn) m3/d ,占比 15.35% ;工地排水水量為0.48萬(wàn) m3/d ,占比 11.51% ;以及較少量的自來(lái)水(水量為0.30萬(wàn) m3/d ,占比 7.19% )和其他外水(水量為0.25萬(wàn) m3/d ,占比 6% )。
4片區(qū)濃度提升方案
4.1工程實(shí)施內(nèi)容
針對(duì)不同類型的外水,本文制定了不同的實(shí)施方案。1)地表水。地表水接入污水管道時(shí),可通過(guò)對(duì)雨污混接/錯(cuò)接改造,將集中地表水導(dǎo)流至雨水系統(tǒng)或新建外水專管后排入水體。2)地下水。地下水主要包括集中入滲和沿線入滲兩種類型。集中入滲點(diǎn)可采用雨污分流,將地下水接入雨水系統(tǒng),通過(guò)雨水排口直排至自然水體。沿線入滲,若采用分流制排水系統(tǒng),可對(duì)沿線管道破損處進(jìn)行修復(fù),避免地下水滲進(jìn)污水系統(tǒng);若采用合流制排水系統(tǒng),則可通過(guò)新建污水管道,將外水排人雨水管道后直排河道。3)工地排水。加強(qiáng)對(duì)工地排水的監(jiān)管,督促施工單位將工地排水接入雨水系統(tǒng)。4)自來(lái)水。加強(qiáng)自來(lái)水管道的巡查與維護(hù),發(fā)現(xiàn)滲漏點(diǎn)及時(shí)反饋相關(guān)單位進(jìn)行搶修。
4.2外水去除效果分析
外水調(diào)查表明,集中外水點(diǎn)水量為4.17萬(wàn) m3/d 基于外水中COD不高于地表水Ⅲ類標(biāo)準(zhǔn)限值(20mg/L 的假定,削減現(xiàn)有外水匯入后,研究區(qū)出水口A8監(jiān)測(cè)點(diǎn)COD可達(dá)到 96.7mg/L ,但不能保證片區(qū)出水COD均穩(wěn)定在目標(biāo)值 100mg/L ,因此需要進(jìn)一步對(duì)片區(qū)范圍內(nèi)流量大、COD低的源頭區(qū)域進(jìn)行改造。
源頭改造方案出水目標(biāo)為出水 COD130mg/L 或現(xiàn)狀流量削減不超過(guò) 60% ,源頭地塊外水混入后COD按照現(xiàn)有外水實(shí)測(cè)質(zhì)量濃度 19.7mg/L 計(jì)算。選取片區(qū)范圍內(nèi)14個(gè)源頭地塊(總面積 41.3ha 進(jìn)行改造,改造后W8片區(qū)總出水COD達(dá)到 115.8mg/L 。此外相關(guān)研究表明,當(dāng)輸送距離 ?5km 時(shí),污水中污染物降解率一般 ?10%[6] ,因此本文考慮 10% 的水質(zhì)沿程衰減,仍能確保片區(qū)出水COD質(zhì)量濃度達(dá)到104.2mg/L
5結(jié)論及建議
污水管網(wǎng)外水入侵點(diǎn)位的精準(zhǔn)識(shí)別與治理,對(duì)排水系統(tǒng)評(píng)估和提質(zhì)增效改造至關(guān)重要。本研究通過(guò)市政管網(wǎng)監(jiān)測(cè)源頭地塊水質(zhì)水量分析,以及片區(qū)自來(lái)水供水?dāng)?shù)據(jù)對(duì)比,揭示了研究區(qū)污水低濃度的成因,可項(xiàng)目決策提供較為堅(jiān)實(shí)的科學(xué)依據(jù)。
研究結(jié)論如下。1)源頭地塊出水平均COD僅為86.4mg/L ,污水濃度總體偏低。背后原因主要為現(xiàn)狀源頭地塊管網(wǎng)建設(shè)質(zhì)量差、運(yùn)維管理缺失,導(dǎo)致排水管網(wǎng)混錯(cuò)接普遍。2)研究區(qū)總出口平均COD僅為78.3mg/L ,片區(qū)旱季外水入侵率達(dá) 46.99% ,市政排水管網(wǎng)混錯(cuò)接外水入侵比例高,主要外水類型為山泉水入侵、地下水人滲、自來(lái)水爆管等。3)根據(jù)水質(zhì)水量監(jiān)測(cè)數(shù)據(jù)結(jié)果,片區(qū)主要外水入侵區(qū)域?yàn)閃8-6和W8-7區(qū)域,擬通過(guò)實(shí)施針對(duì)性措施來(lái)撇除外水,并輔以小范圍的源頭地塊雨污分流改造,以實(shí)現(xiàn)研究區(qū)總出口COD達(dá)到 100mg/L 的水質(zhì)目標(biāo)
建議下一階段持續(xù)監(jiān)測(cè)重點(diǎn)區(qū)域和管道,有針對(duì)性地開(kāi)展提質(zhì)增效工作,進(jìn)一步提升污水處理廠進(jìn)水污染物濃度,實(shí)現(xiàn)節(jié)能降耗、降本增效,提高排水系統(tǒng)整體運(yùn)行效率,促進(jìn)城市可持續(xù)發(fā)展。
參考文獻(xiàn)
[1]國(guó)家統(tǒng)計(jì)局.中國(guó)統(tǒng)計(jì)年鑒:2021[M].北京:中國(guó)統(tǒng)計(jì)出版社,2021.
[2]劉戰(zhàn)廣,譚學(xué)軍,陳嫣.基于水量平衡分析的城鎮(zhèn)污水管網(wǎng)定性診斷研究[J].給水排水,2020,56(9):113-118.
[3]謝家強(qiáng),胡軍,顏瑩瑩,等.長(zhǎng)江經(jīng)濟(jì)帶典型污水收集系統(tǒng)提質(zhì)增效量化研究[J].中國(guó)給水排水,2022,38(19):28-34.
[4]郭帥,張土喬,ZHUD.地下水滲入排污管道的定量方法[J].中國(guó)給水排水,2013,29(4):21-25.
[5]周小國(guó),惠二青,彭壽海,等.長(zhǎng)江沿線污水處理廠進(jìn)水 BOD5 濃度與管網(wǎng)運(yùn)營(yíng)調(diào)查分析[J].給水排水,2021,57(增刊1):129-133.
[6]盧貫?zāi)?淺淡城鎮(zhèn)污水處理廠進(jìn)水COD濃度偏低的原因[J].資源節(jié)約與環(huán)保,2014(6):144.