中圖分類號(hào):TK227.7 文獻(xiàn)標(biāo)志碼:A 文章編號(hào):1000-582X(2025)07-094-10
Dynamic simulation of a ultra-supercritical circulating fluidized bed boiler during main fuel trip and boiler trip
LI Guo13,TAO Xiangyu2, ZHANG Zonglong2, YANG Chen2,DENG Qigang 1,3 ,NIE Li1,3 HE Wei3,LI Weichen'3,LU Jiayi'3,GONG Liming13 Clean Combustion and Flue Gas Purification Key Laboratory of Sichuan Province,Chengdu 611731, : R.China; 2.School of Energy and Power Engineering,Chongqing University,Chongqing 40044,P.R. China; 3. Dongfang Electric Corporation, Dongfang Boiler Group Co.,Ltd., Zigong, Sichuan 6430o1,P.R. China)
Abstract:To investigate the dynamic characteristics ofan ultra-supercritical circulating fluidized bed (CFB)boiler during main fuel trip (MFT) and boiler trip (BT) events, a mathematical model of a 660MW ultra-supercritical CFB boiler was established using the Apros simulation platform.The model dynamically simulates MFT and BT scenarios under coal conbustion conditions at 100% BMCR (boiler maximum continuous rating), 75% THA (turbine heat acceptance) and 50% THA operating loads. Numerical results show that under 50% THA operating conditions,the steam-water separator rapidly transitions from dry to wet operation folowing MFT and BT activationand gradually returns to dry operation after system reset.These frequent dry-wet transitions increase thermal stress on the steam-water separator, potentially reducing its service life and compromising equipment safety.Therefore,triggering MFT and BT under low-load conditions should be avoided to ensure system reliability.
Keywords: ultra-supercritical; circulating fluidized bed boiler; main fuel trip; boiler trip; dynamic simulation
循環(huán)流化床燃燒技術(shù)得益于良好的燃料適應(yīng)性和環(huán)保性能,在國內(nèi)得到了快速發(fā)展,容量更大、參數(shù)更高、環(huán)保性能更好是循環(huán)流化床鍋爐的主要發(fā)展方向[]。2019年國家能源局正式批復(fù)貴州威赫電廠660MW 超超臨界循環(huán)流化床鍋爐示范項(xiàng)目[4],2020年貴州威赫 660MW 超超臨界CFB(circulating fluidizedbed,CFB)鍋爐發(fā)電機(jī)組進(jìn)入建造階段,貴州威赫 660WM 超超臨界CFB鍋爐是目前世界上循環(huán)流化床單機(jī)容量最大、參數(shù)等級(jí)最高、機(jī)組整體性能最先進(jìn)的鍋爐,解決了高硫無煙煤高效、清潔利用的世界難題。
國內(nèi)針對(duì)清潔高效的超超臨界循環(huán)流化床鍋爐已有多項(xiàng)研究[5-8],對(duì)于 660MW 超超臨界CFB鍋爐的子系統(tǒng)的研究也有報(bào)道[],但對(duì) 660MW 超超臨界CFB鍋爐的整體系統(tǒng)特性,尤其是系統(tǒng)動(dòng)態(tài)特性的研究則較少?,F(xiàn)有研究主要關(guān)注鍋爐的子系統(tǒng),如汽水系統(tǒng)、燃燒系統(tǒng)、灰循環(huán)系統(tǒng)等,而針對(duì) 660MW 超超臨界CFB鍋爐系統(tǒng)級(jí)的仿真研究少有報(bào)道。研究鍋爐整體的動(dòng)態(tài)特性,特別是事故工況下鍋爐的動(dòng)態(tài)響應(yīng),對(duì)CFB鍋爐的安全有效運(yùn)行具有重要意義。文中利用APROS仿真支撐軟件建立了 660MW 超超臨界CFB鍋爐整體動(dòng)態(tài)仿真模型,研究了 660MW 超超臨界CFB鍋爐運(yùn)行時(shí)的動(dòng)態(tài)特性,包括主燃料跳閘(masterfueltrip,MFT)和鍋爐跳閘(boilertrip,BT)。
1系統(tǒng)模型
1.1 鍋爐本體
文中建立數(shù)學(xué)模型的對(duì)象為貴州威赫 660MW 超超臨界循環(huán)流化床鍋爐,布置圖如圖1所示,該鍋爐采用單爐膛,褲叉腿結(jié)構(gòu)。一次風(fēng)由底部的布風(fēng)板進(jìn)人爐膛,使?fàn)t膛底部的床層處于流化態(tài)。在一次風(fēng)作用下,床料從底部爐膛向上運(yùn)動(dòng)。隨著爐膛升高,固體向上運(yùn)動(dòng)速度逐漸減小,在爐膛壁面附近向下運(yùn)動(dòng),形成爐膛內(nèi)的物料循環(huán)過程。爐膛出口的顆粒物被旋風(fēng)分離器捕獲進(jìn)入外置床并從返料器返回爐膛,形成物料的外部循環(huán)。
圖1循環(huán)流化床鍋爐布置示意圖 Fig.1 Layout of circulating fluidizedbed boiler
1.2CFB爐膛的氣固兩相流動(dòng)與傳熱模型
1.2.1 氣固兩相流動(dòng)模型
CFB爐膛氣固兩相流動(dòng)基于“核心-環(huán)\"模型,由于爐膛內(nèi)顆粒物濃度的分布不均勻,中心核心區(qū)固體顆粒濃度較低向上運(yùn)動(dòng),壁面附近固體顆粒濃度較高圍繞核心區(qū)向下運(yùn)動(dòng)形成環(huán)狀區(qū),構(gòu)成“核心-環(huán)\"流動(dòng)結(jié)構(gòu),如圖2所示[12]。
圖2CFB中“核心-環(huán)”流動(dòng)結(jié)構(gòu)示意圖
在APROS仿真模型中,CFB爐膛沿爐膛高度方向劃分為若干個(gè)節(jié)點(diǎn),每個(gè)節(jié)點(diǎn)包含1對(duì)“核心-環(huán)”,按照固體顆粒的濃度分布,將爐膛分為底部密相區(qū)和上部稀相區(qū),如圖3所示[13-14]。
Fig.2Schematicdiagramofthe\"core-ring\"flowstructure inCFB
圖3APROS中CFB的\"核心-環(huán)\"模型 Fig.3The \"core-ring\"model of CFB in APROS
1)稀相區(qū):每一個(gè)氣相節(jié)點(diǎn)包含2個(gè)固相節(jié)點(diǎn)(“核心-環(huán)\"對(duì)),用分流系數(shù)調(diào)節(jié)“核心-環(huán)\"對(duì)之間的固體質(zhì)量輸運(yùn),最上部節(jié)點(diǎn)與旋風(fēng)分離器相連。在核心區(qū),固體顆粒向下運(yùn)動(dòng),在環(huán)狀區(qū)向下運(yùn)動(dòng)。
2)界面層(interfacelayer):提供稀相區(qū)求解的邊界條件,是一個(gè)虛擬的界面。
3)底部床層(high-densitybed):只有一個(gè)節(jié)點(diǎn),假定固體顆?;旌暇鶆?。
1.2.2 傳熱模型
爐膛內(nèi)的傳熱發(fā)生在爐內(nèi)氣固兩相流與各受熱面之間,如圖4所示[14]。
圖4APROS中CFB的傳熱模型
Fig.4HeattransfermodelofCFBinAPROS
傳熱模型簡化為:
1)爐膛內(nèi)氣固兩相之間充分換熱,氣固兩相溫度相等;
2)“核心-環(huán)”之間只有通過質(zhì)量輸運(yùn)產(chǎn)生的能量交換,忽略熱擴(kuò)散;
3)將氣-固兩相與水冷壁之間的傳熱簡化為只有氣相與水冷壁進(jìn)行傳熱。
努塞爾數(shù) Nus,g[15]
式中: εs,mf 表示最小流化速度下的固相體積分?jǐn)?shù); ρg,ρs 分別為氣相和固相密度; ΔL 為節(jié)點(diǎn)高度; g 為重力加速度; Re 為雷諾數(shù); Pr 為普朗特?cái)?shù)。
節(jié)點(diǎn)壓損 Δp 計(jì)算式為
式中: Ab 為節(jié)點(diǎn)面積; ms 為節(jié)點(diǎn)內(nèi)質(zhì)量。壓力損失系數(shù)計(jì)算為
式中, ug 為氣相速度。床層和燃料的熱擴(kuò)散采用以下公式計(jì)算。用2個(gè)相鄰節(jié)點(diǎn) i 和 (i+1) 計(jì)算由于顆粒運(yùn)動(dòng)產(chǎn)生的熱擴(kuò)散[15]:
式中: 為定壓比熱容; Dth 是熱擴(kuò)散系數(shù); mi 為節(jié)點(diǎn) i 中質(zhì)量; Ti 和 Ti+1 分別為節(jié)點(diǎn) i 和 (i+1) 的平均溫度。
燃料擴(kuò)散的擴(kuò)散速度為
式中: mi,fuel 和 mi+1,fuel 分別為節(jié)點(diǎn) i 和 i+1 中的燃料。
平均床溫為
式中: Vi 為節(jié)點(diǎn) i 的體積; Vtot,bed 為床層總體積。
1.4 煙風(fēng)系統(tǒng)
1.4.1一次風(fēng)系統(tǒng)
一次風(fēng)經(jīng)空氣預(yù)熱器加熱后,作為一次燃燒用風(fēng)和流化風(fēng)進(jìn)入爐膛底部的水冷風(fēng)室,通過布置在布風(fēng)板上的風(fēng)帽使床料流化,形成向上流動(dòng)的氣固兩相流。
1.4.2 二次風(fēng)系統(tǒng)
二次風(fēng)經(jīng)暖風(fēng)器,空氣預(yù)熱器加熱后分為2層,進(jìn)入爐膛下部內(nèi)側(cè)及外側(cè),作為燃燒以及燃燒調(diào)整用風(fēng)。
1.4.3 煙氣系統(tǒng)
燃料燃燒產(chǎn)生的熱煙氣將熱量傳遞給爐膛水冷壁,然后流經(jīng)旋風(fēng)分離器,進(jìn)入后豎井包墻,墻內(nèi)布置有低溫過熱器、低溫再熱器和省煤器。煙氣再進(jìn)入煙氣給水加熱器和空氣預(yù)熱器,最后進(jìn)入除塵器,流向煙肉,排向大氣。
圖5CFB的煙-風(fēng)系統(tǒng)示意圖
Fig.5Schematic diagram of the air-flu gas system
1.5 汽水系統(tǒng)
1.5.1 氣液兩相流動(dòng)模型
為了精確地模擬汽水系統(tǒng)“氣-液\"兩相流動(dòng)的動(dòng)態(tài)特性,采用氣液兩相流動(dòng)的“六方程\"模型。氣液兩相流模型分別針對(duì)氣相以及液相建立質(zhì)量守恒、能量守恒以及動(dòng)量守恒方程。汽水側(cè)氣液兩相流數(shù)學(xué)模型如下所示[1]:
質(zhì)量守恒:
動(dòng)量守恒:
能量守恒:
式中:下標(biāo) k 表示氣體和液體中任意一種;下標(biāo) i 和 w 分別表示兩相與壁面接觸面; T 表示兩相之間質(zhì)量交換率; F 表示摩擦力; 表示熱量;動(dòng)量方程后3項(xiàng)分別表示閥門摩擦力、沿程摩擦和泵的壓頭,能量方程中 h 表示考慮了動(dòng)能在內(nèi)的總焓。
1.5.2 過熱蒸汽系統(tǒng)
鍋爐給水從給水泵出口進(jìn)入煙氣給水加熱器,吸收煙氣熱量后進(jìn)入省煤器,由省煤器出口集箱經(jīng)連接管進(jìn)入水冷壁入口集箱,從水冷壁出口的蒸汽(或汽水混合物)進(jìn)入汽水分離器。在鍋爐低負(fù)荷運(yùn)行時(shí),水冷壁出口為汽水混合物,經(jīng)汽水分離器后疏水進(jìn)入儲(chǔ)水罐,蒸汽則依次流經(jīng)旋風(fēng)分離器入口煙道、后豎井包墻、吊掛管、低溫過熱器,再流經(jīng)爐膛內(nèi)的中溫過熱器,最后流經(jīng)外置床中的高溫過熱器。過熱蒸汽溫度是由水-煤比和三級(jí)噴水減溫來控制。第一級(jí)減溫器布置在低溫過熱器(low temperature superheater,LTS)出口和一級(jí)中溫過熱器(intermediate temperature superheater1,ITS1)之間;第二級(jí)減溫器布置在二級(jí)中溫過熱器(ITS2)出口和一級(jí)高溫過熱器(high temperature superheater1,HTS1)之間;第三級(jí)減溫器布置在一級(jí)高溫過熱器和二級(jí)高溫過熱器(HTS2)之間,減溫水來自省煤器出口。
圖6過熱蒸汽系統(tǒng)示意圖
Fig.6Schematicdiagramof thesuperheatedsteamsystem
1.5.3 再熱蒸汽系統(tǒng)
從汽輪機(jī)高壓缸抽取的再熱蒸汽依次流經(jīng)尾部煙道中的低溫再熱器(low temperature reheater,LTR)和外置床中的高溫再熱器(high temperature reeater,HTR),最后引人汽輪機(jī)中壓缸。再熱蒸汽汽溫主要通過調(diào)節(jié)外置床中高溫再熱器的灰流量實(shí)現(xiàn),在低溫再熱器出口管道上布置有事故減溫水,作為事故狀態(tài)下的調(diào)節(jié)手段。
2 仿真結(jié)果分析
2.1 模型的穩(wěn)態(tài)校核
研究主要在 100% BMCR、 75% THA和 50% THA工況下進(jìn)行,分別以上述3種的穩(wěn)態(tài)工況進(jìn)行穩(wěn)態(tài)校核驗(yàn)證。 100%BMCR、75%THA 和 50% THA工況下主要參數(shù)的設(shè)計(jì)值和仿真值如表1所示??梢钥闯?,3種工況下的主要參數(shù)的相對(duì)誤差均在 1% 以內(nèi),個(gè)別參數(shù)誤差在 5% 以內(nèi),說明該模型在上述3種工況下均有良好的仿真精度,能夠滿足仿真要求。
圖7給出了不同工況下,爐膛內(nèi)溫度以及固體顆粒物濃度分布??梢钥闯?,隨著爐膛高度升高,爐膛內(nèi)溫度逐漸降低。顆粒物濃度隨著爐膛高度升高而降低,底部床層密度明顯高于上部稀相區(qū)。
'able1Steadystatesimulationresultsof 100% BMCR/75%THA/50%THA
2.2 主燃料跳閘(MFT)仿真分析
主燃料跳閘是指鍋爐的安全運(yùn)行條件得不到滿足、需要緊急停爐而發(fā)出指令快速切斷所有通往爐膛的燃料并引發(fā)必要的連鎖動(dòng)作,避免對(duì)鍋爐的潛在危害,以保護(hù)鍋爐爐膛、其它設(shè)備及運(yùn)行人員的安全。鍋爐發(fā)出MFT后,將伴隨以下動(dòng)作:
1)給煤、油切除;
2)石灰石切除;
3)外置床跳閘;
4)減溫水總門關(guān)閉;
5)所有風(fēng)量控制改為手動(dòng)方式,并保持最后位置;
6)冷渣器切除。
在 100% BMCR、 75% THA和 50% THA工況下,鍋爐觸發(fā)MFT,此時(shí)給煤量快速降為0。由于循環(huán)流化床鍋爐爐膛內(nèi)有大量高溫床料,具有極強(qiáng)的蓄熱能力,給煤量降為0后,蒸汽依然從爐膛吸熱維持一定的過熱度。在觸發(fā)MFT后,由于主燃料切除,鍋爐給水快速降低,從而維持床溫以及主蒸汽、再熱蒸汽溫度的相對(duì)穩(wěn)定。 5min 后MFT復(fù)位,鍋爐進(jìn)入熱態(tài)啟動(dòng),此時(shí)給煤量升高,外置床換熱器灰流量逐漸升高。 100% BMCR工況下約 60min 后,主蒸汽和再熱蒸汽溫度、流量恢復(fù)到設(shè)定值; 75% THA工況下 40min 后,主蒸汽和再熱蒸汽溫度、流量恢復(fù)到設(shè)定值。 50% THA工況下 30min 后,分離器由濕態(tài)逐漸轉(zhuǎn)為干態(tài)運(yùn)行,約50min 后,主蒸汽和再熱蒸汽溫度、流量恢復(fù)到設(shè)定值。鍋爐各參數(shù)變化示意圖,如圖8所示。
圖8不同工況下MFT過程中各參數(shù)變化示意圖Fig.8Parametersof CFBboilerduringtheMFT process
從 100% BMCR、 75% THA、 50% THA工況下MTF結(jié)果可以看出,在 50% THA工況下觸發(fā)MFT后,由于50% THA工況時(shí)負(fù)荷較低,觸發(fā)MFT后汽水分離器由干態(tài)轉(zhuǎn)為濕態(tài)運(yùn)行,當(dāng)MFT復(fù)位后,又逐漸由濕態(tài)轉(zhuǎn)為干態(tài)。頻繁干濕態(tài)轉(zhuǎn)換會(huì)使汽水分離器產(chǎn)生較大熱應(yīng)力,影響設(shè)備安全,應(yīng)避免在低負(fù)荷下觸發(fā)MFT。
2.3 鍋爐跳閘(BT)仿真分析
當(dāng)觸發(fā)鍋爐跳閘(BT)時(shí),爐膛內(nèi)仍有大量未燃盡燃料,為了保護(hù)鍋爐安全,必須切斷所有通人爐膛的物料。與鍋爐MFT相比,當(dāng)鍋爐觸發(fā)BT后,除了需要切斷煤、石灰石外,還需要切斷通往爐膛的一次風(fēng)以及二次風(fēng),盡可能降低爐膛的燃燒,保證爐膛的安全。鍋爐觸發(fā)BT后,鍋爐側(cè)將伴隨以下動(dòng)作:
1)給煤、油切除;
2)石灰石切除;
3)外置床跳閘;
4)減溫水總門關(guān)閉;
5)所有風(fēng)量控制改為手動(dòng)方式,并保持最后位置;
6)冷渣器切除;
7)一次風(fēng)機(jī)、二次風(fēng)機(jī)、引風(fēng)機(jī)跳閘。
在 100% BMCR、 75% THA和 50% THA工況下,觸發(fā)鍋爐BT??梢钥闯觯湾仩tMFT相比,由于BT時(shí)一次風(fēng)機(jī)、二次風(fēng)機(jī)、引風(fēng)機(jī)均跳閘,煙氣無法將熱量從爐膛內(nèi)帶走,因此爐膛溫度比MFT后溫度要高。觸發(fā)BT后 5min ,鍋爐開始極熱態(tài)啟動(dòng),在 100% BMCR工況下,約 60min 后主蒸汽、再熱蒸汽溫度、流量達(dá)到額定值;在 75% THA工況下,約 55min 后主蒸汽、再熱蒸汽溫度、流量達(dá)到額定值;在 50% THA工況下鍋爐觸發(fā)BT后,約 8min ,分離器由干態(tài)逐漸轉(zhuǎn)為濕態(tài),液位控制在 6.5m 。此后,鍋爐BT復(fù)位,給煤量、風(fēng)量、給水量逐漸增加,約 25min 后分離器由濕態(tài)逐漸轉(zhuǎn)為干態(tài),蒸汽溫度、床溫、外置床灰溫不斷升高, 40min 后各參數(shù)逐漸恢復(fù)到 50% THA。鍋爐各參數(shù)變化示意圖,如圖9所示。
從 100% BMCR、 75% THA、 50% THA工況下BT結(jié)果可以看出,與MFT結(jié)果類似,在 50% THA工況下觸發(fā)BT后,由于 50%THA 工況時(shí)負(fù)荷較低,觸發(fā)BT后汽水分離器由干態(tài)轉(zhuǎn)為濕態(tài)運(yùn)行,當(dāng)BT復(fù)位后,又逐漸由濕態(tài)轉(zhuǎn)為干態(tài)。頻繁干濕態(tài)轉(zhuǎn)換會(huì)使汽水分離器產(chǎn)生較大熱應(yīng)力,影響設(shè)備安全,應(yīng)避免在低負(fù)荷下觸發(fā)BT。
圖9不同工況下BT過程中各參數(shù)變化示意圖
Fig. 9 ParametersofCFBboilerduring the BTprocess
3結(jié)論
文中以貴州威赫 660MW 超超臨界循環(huán)流化床鍋爐為研究對(duì)象,通過仿真軟件APROS建立了CFB鍋爐的動(dòng)態(tài)仿真數(shù)學(xué)模型,分別在 100%BMCR 、 75% THA和 50%THA 工況下,進(jìn)行模型穩(wěn)態(tài)驗(yàn)證和動(dòng)態(tài)仿真試驗(yàn),研究CFB鍋爐觸發(fā)MFT和BT時(shí)的動(dòng)態(tài)變化特性,得到如下結(jié)論。
1)模型穩(wěn)態(tài)仿真結(jié)果表明,文中所建模型在 100% BMCR、 75% BMCR以及 50% BMCR工況下,主要參數(shù)誤差均小于 1% ,展示了良好的仿真精度。同時(shí),爐膛內(nèi)溫度以及顆粒物濃度的分布表明,所建模型能準(zhǔn)確反映爐膛內(nèi)-固兩相流動(dòng)的特性。
2)不同工況下的MFT仿真結(jié)果顯示,當(dāng)觸發(fā)MFT后,盡管主燃料切除,但由于爐膛內(nèi)仍有大量未燃盡床料在繼續(xù)燃燒,蒸汽依然可以從爐膛吸熱并維持一定過熱度。隨著爐膛內(nèi)殘余燃料燃盡,爐膛發(fā)熱量逐漸降低,床層溫度以及主蒸汽、再熱蒸汽溫度均逐漸降低。在 50% BMCR工況下,鍋爐觸發(fā)MFT后汽水分離器由干態(tài)逐漸轉(zhuǎn)為濕態(tài)運(yùn)行。MFT復(fù)位后,鍋爐進(jìn)人熱態(tài)啟動(dòng),給煤量逐漸升高,床層溫度、主蒸汽溫度以及再熱蒸汽溫度均逐漸升高恢復(fù)至設(shè)定值。
3)與鍋爐MFT相比,鍋爐觸發(fā)BT后由于一次風(fēng)機(jī)、二次風(fēng)機(jī)、引風(fēng)機(jī)均跳閘,煙氣無法將熱量從爐膛內(nèi)帶走,鍋爐觸發(fā)BT后床層溫度比MFT后高。與MFT類似,在 50% BMCR工況下,鍋爐觸發(fā)BT后汽水分離器逐漸由干態(tài)轉(zhuǎn)為濕態(tài)運(yùn)行。BT復(fù)位后,床層溫度、主蒸汽、再熱蒸汽溫度均不斷升高恢復(fù)至設(shè)定值,50% BMCR工況下,汽水分離器逐漸從濕態(tài)轉(zhuǎn)為十態(tài)運(yùn)行。
4)結(jié)合鍋爐MFT、BT工況可以發(fā)現(xiàn),在 50% BMCR工況下,汽水分離器均會(huì)經(jīng)歷干態(tài)-濕態(tài)-干態(tài)的變化,干濕態(tài)轉(zhuǎn)換會(huì)增大汽水分離器的熱應(yīng)力,應(yīng)避免在低負(fù)荷下觸發(fā)鍋爐MFT和BT,以保證鍋爐的安全、穩(wěn)定運(yùn)行。
參考文獻(xiàn)
[1]辛勝偉,王虎.超超臨界循環(huán)流化床鍋爐發(fā)展及主要技術(shù)特性探討[J].煤炭工程,2017,49(S1):99-103. XinSW,Wang H.Progressandmaintechnicalcharacteristicsofultrasupereritical circulatingfluidizedbedboiler[J].Coal Engineering,2017,49(S1): 99-103.(in Chinese)
[2]岳光溪,呂俊復(fù),徐鵬,等.循環(huán)流化床燃燒發(fā)展現(xiàn)狀及前景分析[J].中國電力,2016,49(1):1-13. Yue GX,LyuJF,XuP,etal.Theup-to-datedevelopmentand futureofcirculating fluidized bedcombustiontechnology[J]. Electric Power,2016,49(1):1-13.(in Chinese)
[3]Cheng LM,JiJQ,WeiYJ,etal.Anoteonlarge-sizesupercriticalCFBtechnologydevelopment[J].PowderTechnology 2020,363:398-407.
[4]東方電氣網(wǎng).世界單機(jī)容量最大、參數(shù)最高、整體性能世界領(lǐng)先的循環(huán)流化床機(jī)組項(xiàng)目獲批國家電力示范項(xiàng)目[J].東方電 氣評(píng)論,2019,33(1):23. Dongfang Electric Network.Thecirculating fluidizedbedunit projectwith thelargestsingleunitcapacity,thehighest parameters andtheworld-leadingoverallperformanceintheworld wasappovedasanationalpowerdemonstrationproject[J]. DongfangElectric Review,2019,33(1):23.(in Chinese)
[5]高新宇,王鳳君,王君峰,等.哈鍋 660MW 高效超超臨界循環(huán)流化床鍋爐方案研究[J].鍋爐制造:2021(2):10-12,27. Gao X Y, Wang FJ, Wang JF, et al. A design scheme of 660MW ULTRA-supercritical CFB boiler[J]. Boiler Manufacturing, 2021(2):10-12,27. (in Chinese)
[6]凌文,呂俊復(fù),周托,等. 660MW 超超臨界循環(huán)流化床鍋爐研究開發(fā)進(jìn)展[J].中國電機(jī)工程學(xué)報(bào),2019,39(9):2515-2524. Ling W,LyuJF,ZhouT,etal.Researchanddevelopmentprogressofthe660MWultra-supercriticalcirculatingfluidizedbed boiler[J].Proceedings of the CSEE,2019,39(9): 2515-2524.(in Chinese)
[7]聶立. 660MW 超超臨界循環(huán)流化床鍋爐關(guān)鍵技術(shù)與方案研究[D].杭州:浙江大學(xué),2021. NieL. Study on key technologies and scheme of 660MW ultra supercritical circulating fluidized bed boiler[D]. Hangzhou: Zhejiang University,2021.(in Chinese)
[8]Nie L,Lu JY, DengQ G,et al. Study on the uniformity of secondary air of a 660MW ultra-supercritical CFB boiler[J]. Energies,2022,15(10): 3604.
[9]TangGL,Zhang M,GuJP,etal.Thermal-hydrauliccalculationand analysisonevaporator systemofa 660 MWe ultrasupercritical CFB boiler[J].Applied Thermal Engineering,2019,151: 385-393.
[10]ZhouXH,NiuTT,XinYF,etal.Experimentalandnumericalivestigationonheattransferintheverticalupwardflowwater wallof a 660MWultra-supercritical CFB boiler[J].Applied Thermal Engineering,2021,188:11664.
[11] Zhu S H, Zhang M, Huang YQ,et al. Thermodynamic analysis of a 660MW ultra-supercritical CFB boiler unit[J]. Energy, 2019,173:352-363.
[12]Heimo H.Dynamiccore-annulus model of circulating fluidizedbedboilers[D].Finland Masterthesis,Lappeeranta University of Technology,2018.
[13]Yang C,Zhang Z L, Wu HC,etal. Dynamic characteristics analysis ofa660MWultra-supererical circulating fluidizedbed boiler[J].Energies,2022,15(11): 4049.
[14]LappalainenJ,HidenkariH,TuuriS,etal.Dynamiccore-annulus modelforcirculatingfluidizedbedboilers[C/NordicFlame Days2019.August 28-29,2019, Turku,F(xiàn)inland: IEEE,2019:1-5.
[15]Apros.User manual: apros 6 feature tutorial; version 6.09[J].VTTamp; Fortum:Espoo,F(xiàn)inland,2019.
[16]鐘晶亮,鄧康杰,楊晨.關(guān)于超臨界直流鍋爐的啟動(dòng)仿真研究[J].計(jì)算機(jī)仿真,2018,35(12):96-99,170. ZhongJL,DengKJ,Yang C.Researchonstart-upsimulationofsupereriticalonce-throughboiler[J].Computer Simulation, 2018,35(12): 96-99,170.(in Chinese)