章厲劼 王慶紅 金曉峰
摘 要:建立了獸藥磺胺對(duì)甲氧嘧啶片中磺胺對(duì)甲氧嘧啶含量的高效液相色譜測(cè)定法。以十八烷基硅烷鍵合硅膠為填充劑,0.1%磷酸溶液-乙腈(80:20)為流動(dòng)相,檢測(cè)波長(zhǎng)為270nm,流速為1.0mL/min,柱溫40℃,采用外標(biāo)法進(jìn)行定量?;前穼?duì)甲氧嘧啶的線性范圍0.005~0.10mg/mL,回歸方程為Area=71641.62×Amt+3.01(n=5),相關(guān)系數(shù)大于0.99999?;前穼?duì)甲氧嘧啶片中磺胺對(duì)甲氧嘧啶三個(gè)添加濃度的添加回收率均均在98.2%~103.0%之間,RSD分別為0.51%、1.1%、0.87%。該方法簡(jiǎn)單,準(zhǔn)確,穩(wěn)定性,精密度好,回收率高,可以用于測(cè)量磺胺對(duì)甲氧嘧啶片中磺胺對(duì)甲氧嘧啶的含量。
關(guān)鍵詞:磺胺對(duì)甲氧嘧啶片;磺胺對(duì)甲氧嘧啶;高效液相色譜
Abstract:An HPLC method has been devloped to determine the content of sulfamethoxydiazine in sulfamethoxydiazine Tablets. With eighteen alkyl silane bonded silica as filler, 0.1% phosphoric acid solution - acetonitrile (80:20) as mobile phase. The detection wavelength is 270nm, the flow rate is 1.0mL/min, the column temperature is 40 degrees Celsius, Quantitatively by external standard method. Sulfamethoxydiazine in the linear range of 0.005~0.10 mg/mL, the regression equation is Area=71641.62×Amt+3.01(n=5), The correlation coefficient is greater than 0.99999. Sulfamethoxydiazine tablets sulfamethoxydiazine add three concentrations were between recoveries were 98.2%~103.0%, and RSD were 0.51%, 1.1%, 0.87%. The method is simple, accurate, stability, precision, high recovery rate, can be used to measure sulfamethoxydiazine Tablets methoxy pyrimidine sulfonamides content.
Key words:sulfamethoxydiazine tablets;sulfamethoxydiazine;HPLC
磺胺對(duì)甲氧嘧啶(C11H12N4O3,簡(jiǎn)稱SMD)作為一種磺胺類(lèi)藥,屬于長(zhǎng)效磺胺?;前穼?duì)甲氧嘧啶用于控制畜禽細(xì)菌性疾病和雞球蟲(chóng)病[ 9 ],對(duì)革蘭氏陰性菌有效,對(duì)化膿性鏈球菌、肺炎球菌、傷寒桿菌、沙門(mén)氏菌、鼠疫桿菌、和肺炎桿菌均有良好的抗菌作用,常用作飼料添加劑及畜禽疾病的治療和預(yù)防[ 7 ]。
其具有乙酰化率低,毒性和副作用小,主要經(jīng)腎臟排泄等優(yōu)點(diǎn)[ 8 ]。《中華人民共和國(guó)獸藥典》中磺胺對(duì)甲氧嘧啶片[ 1 ]中磺胺對(duì)甲氧嘧啶的含量測(cè)定采用的是永停滴定法,但在實(shí)際檢測(cè)中,發(fā)現(xiàn)該方法穩(wěn)定性差,懷疑可能是制劑中的輔料干擾了電極的感應(yīng),有些廠家生產(chǎn)的磺胺對(duì)甲氧嘧啶片用永停滴定法根本無(wú)法準(zhǔn)確的檢測(cè)磺胺對(duì)甲氧嘧啶的含量,不能有效進(jìn)行質(zhì)量控制。
本研究建立了磺胺對(duì)甲氧嘧啶片中磺胺對(duì)甲氧嘧啶含量的高效液相色譜測(cè)定法,并根據(jù)《中華人民共和國(guó)獸藥典》中“獸藥中藥質(zhì)量標(biāo)準(zhǔn)分析方法驗(yàn)證指導(dǎo)原則”[ 1 ]對(duì)新建方法的準(zhǔn)確度、精密度、專屬性、耐用性、穩(wěn)定性及線性等進(jìn)行了研究。
1 材料
1.1 儀器和試藥
Agilent 1260 Infiinity高效液相色譜儀(配紫外檢測(cè)器);
ZYT-1全自動(dòng)永停滴定儀(無(wú)錫科達(dá));
超聲波清洗器(KQ-300DE,昆明市超聲儀器廠);
BP211D型電子分析天平(德國(guó)賽多利斯公司);
磺胺對(duì)甲氧嘧啶鈉對(duì)照品(Dr.Ehernstorfer GmbH公司,批號(hào):10228,含量:99.0%);
磺胺對(duì)甲氧嘧啶原料(湖北欣達(dá)利生化有限公司,批號(hào)為:20121001)試驗(yàn)樣品由成都乾坤動(dòng)物藥業(yè)有限公司生產(chǎn)提供(批號(hào):20130101、20130102、20130103,規(guī)格:0.5g);
乙腈(色譜純);
水為超純水;其他試劑為分析純。
2 方法
2.1 藥典方法
《中華人民共和國(guó)獸藥典》2010年版一部中“磺胺對(duì)甲氧嘧啶片”含量測(cè)定項(xiàng)下方法[ 1 ] 。
2.2 色譜方法
2.2.1 色譜條件
色譜柱:Luna 5μ C18(2) 5μm 4.6×250mm;柱溫:40℃;0.1%磷酸溶液-乙腈(80:20)為流動(dòng)相;流速:1.0mL/min;檢測(cè)波長(zhǎng)為270nm[ 3 ];進(jìn)樣體積為20μL。
2.2.2 對(duì)照品溶液的制備
取磺胺對(duì)甲氧嘧啶鈉對(duì)照品約54mg(相當(dāng)于含磺胺對(duì)甲氧嘧啶50mg),精密稱定,置50ml量瓶中,加鹽酸10mL,超聲處理(功率250W,頻率20kHz)5分鐘,取出,加水稀釋至刻度。即得濃度為1.0mg /mL的磺胺對(duì)甲氧嘧啶對(duì)照品儲(chǔ)備溶液。精密量取5mL濾液置于100mL容量瓶中,加流動(dòng)相稀釋至刻度,即得50μg/mL的磺胺對(duì)甲氧嘧啶對(duì)照溶液。
2.2.3 供試樣品處理
取本品10片,精密稱定,研細(xì),精密稱取適量(約相當(dāng)于磺胺對(duì)甲氧嘧啶0.2g)置200ml量瓶中,加鹽酸10mL,超聲處理(功率250W,頻率20kHz)5分鐘,取出,加水稀釋至刻度。精密量取5mL濾液置于100mL容量瓶中,加流動(dòng)相稀釋至刻度,搖勻,濾過(guò),取續(xù)濾液,即得供試品溶液。
3 結(jié)果
3.1 藥典方法
取成都乾坤動(dòng)物藥業(yè)有限公司提供的批號(hào)為20130101、20130102、20130103的磺胺對(duì)甲氧嘧啶片及湖北欣達(dá)利生化有限公司生產(chǎn)的批號(hào)為20121001的磺胺對(duì)甲氧嘧啶原料藥物按2.1項(xiàng)進(jìn)行處理測(cè)定。以測(cè)定結(jié)果的相對(duì)偏差RSD表示試驗(yàn)的精密度,RSD分別為8.30%、4.86%、13.96%、0.18%。
可見(jiàn)成都乾坤動(dòng)物藥業(yè)有限公司提供的磺胺對(duì)甲氧嘧啶片檢測(cè)結(jié)果穩(wěn)定性差,偏差較大,而磺胺對(duì)甲氧嘧啶原料藥物的檢測(cè)結(jié)果穩(wěn)定性較好。
原因可能是成藥制劑中某種輔料對(duì)電極的電流造成干擾,使全自動(dòng)永停滴定儀無(wú)法準(zhǔn)確判斷終點(diǎn),而原料藥物中沒(méi)有這種輔料,所有電極不受干擾,檢測(cè)結(jié)果穩(wěn)定、偏差小。結(jié)果見(jiàn)表1。
3.2 色譜方法
3.2.1線性范圍
精密量取1.0mg /mL磺胺對(duì)甲氧嘧啶對(duì)照品儲(chǔ)備溶液0.5、1.0、2.5、5.0、10.0mL,分別置于100mL容量瓶中,加流動(dòng)相稀釋至刻度,得含甘草酸濃度分別為0.005、0.01、0.025、0.050、0.10mg/mLmg/mL的對(duì)照溶液系列。注入高效液相色譜儀。
磺胺對(duì)甲氧嘧啶濃度在0.005~0.10mg/mL范圍內(nèi),有良好的線性關(guān)系,回歸方程為Area=71641.62×Amt+3.01(n=5),相關(guān)系數(shù)大于0.99999,對(duì)照品溶液色譜圖及標(biāo)準(zhǔn)曲線見(jiàn)圖1。
3.2.2精密度
取成都乾坤動(dòng)物藥業(yè)有限公司提供的批號(hào)為20130101、20130102、20130103的磺胺對(duì)甲氧嘧啶片各10片,精密稱定,研細(xì)。批號(hào)為20130101稱取6份,批號(hào)為20130102、20130103各取2份,按2.2.3項(xiàng)進(jìn)行處理,每個(gè)樣品進(jìn)樣2針,進(jìn)行含量測(cè)定,以Luna 5μ C18(2) 5μm 4.6×250mm為色譜柱,采用50μg/mL的磺胺對(duì)甲氧嘧啶對(duì)照溶液進(jìn)行單點(diǎn)定量(除非特別說(shuō)明,均以Luna 5μ C18(2) 5μm 4.6×250mm為色譜柱,用50μg/mL的磺胺對(duì)甲氧嘧啶對(duì)照溶液進(jìn)行單點(diǎn)定量計(jì)算,下同)。供試品溶液色譜圖見(jiàn)圖2。RSD分別為0.27%、0.41%、0.16%,表明方法的精密度良好。結(jié)果見(jiàn)表2。
3.2.3準(zhǔn)確性
稱取湖北欣達(dá)利生化有限公司生產(chǎn)的批號(hào)為20121001的磺胺對(duì)甲氧嘧啶原料藥物3份,按2.2.3項(xiàng)進(jìn)行處理,每個(gè)樣品進(jìn)樣2針,進(jìn)行含量測(cè)定。結(jié)果見(jiàn)表3。
稱取2.2中研細(xì)的批號(hào)為20130101的磺胺對(duì)甲氧嘧啶片9份,按高(H)、中(M)、低(L)三個(gè)濃度水平分加添加磺胺對(duì)甲氧嘧啶原料藥物,每個(gè)濃度添加3份,按2.2.3項(xiàng)進(jìn)行處理,每個(gè)樣品進(jìn)樣2針,進(jìn)行含量測(cè)定。結(jié)果見(jiàn)表3。
結(jié)果表明,三個(gè)添加水平的磺胺對(duì)甲氧嘧啶的回收率均在98.2%~103.0%之間,RSD分別為0.51%、1.1%、0.87%,方法具有良好的準(zhǔn)確性。
3.2.4耐用性
取2.2項(xiàng)下處理的樣品,保持流動(dòng)相比例不變,使用Luna 5μ C18(2) 5μm 4.6×250mm色譜柱,柱溫:30℃,流速:0.9mL/min下進(jìn)行測(cè)試,磺胺對(duì)甲氧嘧啶片含量分別為98.2%、96.0%、97.8%;使用安捷倫 ZORBAX SB-C18 5μm 4.6×250mm,柱溫:40℃,流速:1.0mL/min下進(jìn)行測(cè)試,磺胺對(duì)甲氧嘧啶片含量分別為97.2%、95.8%、97.3%。三種色譜條件下測(cè)定結(jié)果無(wú)明顯差異,說(shuō)明耐用性良好。
3.2.5專屬性
在樣品測(cè)試色譜圖中,標(biāo)準(zhǔn)出峰時(shí)間附件未發(fā)現(xiàn)明顯的干擾峰。取不含磺胺對(duì)甲氧嘧啶的溶液測(cè)定,在磺胺對(duì)甲氧嘧啶的保留時(shí)間,也沒(méi)有對(duì)應(yīng)峰??梢?jiàn)方法的專屬性良好。
3.2.6穩(wěn)定性
取3.2.2的供試品溶液,放置5天后,再次測(cè)定,磺胺對(duì)甲氧嘧啶含量分別為97.4%、96.8 %、97.9%,與3.2.2的測(cè)定結(jié)果無(wú)顯著差異,說(shuō)明穩(wěn)定性好。
4 討論與結(jié)論
4.1 色譜條件的優(yōu)化
參考其他磺胺類(lèi)藥物的含量測(cè)定、磺胺類(lèi)藥物殘留檢測(cè)方法及相關(guān)文獻(xiàn)雜志,高效液相色譜法測(cè)定磺胺對(duì)甲氧嘧啶片中磺胺對(duì)甲氧嘧啶所使用的流動(dòng)相系統(tǒng)有磷酸鹽溶液-甲醇(65+35)[ 3 ]、磷酸二氫鉀(0.5mol/L)-磷酸氫二鈉(0.5mol/L)-甲醇(40:40:20)[ 4 ]、0.017 mol/L磷酸-乙腈(80+20)[ 5 ]、0.1%磷酸溶液-乙腈(90∶18) [ 6 ]等。采用流動(dòng)相為0.1%磷酸溶液-乙腈(80:20)時(shí),配置簡(jiǎn)單,對(duì)色譜柱的柱效損傷小。
磺胺對(duì)甲氧嘧啶的出峰時(shí)間適當(dāng),峰形良好,理論塔板數(shù)均也能達(dá)到《中華人民共和國(guó)獸藥典》[ 1 ]規(guī)定要求。
4.2 樣品處理的優(yōu)化
在進(jìn)行樣品處理的過(guò)程中,分別采用10mL鹽酸、20mL鹽酸、10mL稀鹽酸、10mL 0.4%的NaOH[ 2 ]溶液溶解后,超聲處理5~10min,然后再加水定容。發(fā)現(xiàn)采用10mL鹽酸溶解,可以降低成分制劑中輔料對(duì)磺胺對(duì)甲氧嘧啶的吸附,增強(qiáng)磺胺對(duì)甲氧嘧啶的溶解,從而提高磺胺對(duì)甲氧嘧啶的回收率。且供試品溶液不會(huì)因酸度太高而影響到C18柱的柱效與壽命。
4.3 色譜條件的改變
保持流動(dòng)相比例和流速不變,分別在島津LC2010及Agilent 1260 infinity 色譜儀上分別使用菲羅門(mén)Luna 5μ C18(2) 5μm 4.6×250mm色譜柱和ZORBAX SB-C18 5μm 4.6×250mm色譜柱于30℃及40℃條件下對(duì)樣品進(jìn)行測(cè)試,磺胺對(duì)甲氧嘧啶的保留時(shí)間有變化,但檢測(cè)結(jié)果無(wú)影響??梢?jiàn)方法適用于不同設(shè)備、不同色譜條件下。
4.4 對(duì)比
3.1和3.2.3分別用永停滴定法及高效液相色譜法對(duì)湖北欣達(dá)利生化有限公司生產(chǎn)的批號(hào)為20121001的磺胺對(duì)甲氧嘧啶原料藥物進(jìn)行了含量測(cè)定,含量分別為90.7%和91.3%,兩種方法的結(jié)果偏差為0.33%。可見(jiàn)兩種方法的檢測(cè)結(jié)果基本一致,也證明了高效液相檢測(cè)方法的準(zhǔn)確性與可行性。
4.5 建立磺胺對(duì)甲氧嘧啶片中磺胺對(duì)甲氧嘧啶含量的高效液相色譜法測(cè)定是可行的
各方法學(xué)指標(biāo)均比較理想,可以作為磺胺對(duì)甲氧嘧啶片中磺胺對(duì)甲氧嘧啶含量檢測(cè)標(biāo)準(zhǔn)?,F(xiàn)有方法采用永停滴定法測(cè)量磺胺對(duì)甲氧嘧啶含量,最少操作容易,設(shè)備要求簡(jiǎn)單,運(yùn)行成本低,但測(cè)定時(shí)無(wú)法與磺胺間甲氧嘧啶區(qū)分,還需要作硫酸銅沉淀的鑒別反應(yīng)來(lái)鑒其真?zhèn)?,且遇到輔料對(duì)電極會(huì)造成干擾的情況時(shí),是無(wú)法對(duì)磺胺對(duì)甲氧嘧啶的含量進(jìn)行準(zhǔn)確測(cè)量的。
在科學(xué)日益進(jìn)步,實(shí)驗(yàn)室檢測(cè)條件及檢測(cè)能力不斷提升的時(shí)代,高效液相色譜法更適合于永停滴定法檢測(cè)磺胺對(duì)甲氧嘧啶片中磺胺對(duì)甲氧嘧啶的含量。
參考文獻(xiàn):
[1] 中華人民共和國(guó)獸藥典(2010版一部)[S].北京:中國(guó)農(nóng)業(yè)出版社.
[2] 陳錫龍.HPLC法測(cè)定復(fù)方磺胺對(duì)甲氧嘧啶片中磺胺對(duì)甲氧嘧啶的含量[J].中國(guó)獸藥雜志,2014,48(07):30-33.
[3] 耿士偉,曲斌,姜加華等.QuEChERS-UPLC-MS/MS快速測(cè)定雞肝中七種磺胺類(lèi)藥物殘留[J].中國(guó)獸藥雜志,2011,45(10):16-19.
[4] 劉明生,甘輝群,譚菊.磺胺對(duì)甲氧嘧啶在肉雞組織中的殘留研究[J].飼料工業(yè),2006,27(16):49-52.
[5] 中華人民共和國(guó)農(nóng)業(yè)部.農(nóng)牧發(fā)[2001]38號(hào)文件[S].
[6] 馮學(xué)忠,黎華鵬,盤(pán)苑芷等. HPLC 同時(shí)測(cè)定復(fù)方二甲硝咪唑可溶性粉中地美硝唑、甲氧芐啶、磺胺對(duì)甲氧嘧啶的含量[J].動(dòng)物醫(yī)學(xué)進(jìn)展,2011,32(07):55-60.
[7] 朱蓓蕾.動(dòng)物性食品藥物殘留[M].上海:上海科技出版社,1993:40-46.
[8] 吳國(guó)娟,金昌鉉.磺胺對(duì)甲氧嗜咤在貓?bào)w內(nèi)的藥代動(dòng)力學(xué)研究[M].延邊農(nóng)學(xué)院學(xué)報(bào),1990,02:48-51.
[9] 劉智宏,孫嘩,萬(wàn)仁玲.酶免疫法測(cè)定磺胺對(duì)甲氧啼咤殘留的研究[J].中國(guó)獸藥雜志,1996,30(03):20-22.